Valve/Actuator Stall Test 2010-10-27
We have a requirement in our instrumentation spec which calls for a "stall test" to be performed on actuator/valve assemblies to demonstrate that with the valve jammed at the maximum actuator output,
Actuator instrumentation 2010-10-27
Consider a pneumatic actuator with a positioner, air lock and volume booster on.I can understand the reasoning for putting the air lock last (ie next to the actuator) so when air is locked in there is
SIL for a complete unit as valve,actuator and solenoid 2010-10-27
According to IEC standards, a Safety Integrity Level (SIL) may be defined for a safety-related or safety instrumented system (SIS) with reference to a certain safety function.
Wedge gate valve inline cleaning 2010-10-26
Need mechanism or tool that helps in cleaning (accessing) gate pocket from Fe debris;
Cv vs Position in a Gate Valve 2010-10-26
Gate valves are very loosely guided. You may be able to calculate a Cv for an intermediate position, but in reality the disc will be dancing about and the Cv will be dithering back and forth, without
6 inch gate valve position 2010-10-26
Being asked how many turns it takes to close a 6 inch gate valve for the full open position.
Gate valve, wedge 2010-10-26
If exist some rule in the selection of the wedge type (solid, flexible, parallel slide, double disc, etc) of the gate valve.
Grove gate valve 2010-10-26
The Grove Valve building was a center of heavy industrial activity since 1939, most recently housing Grove Valve and Steel until 1996.